Type and NameÂ
Type | Name |
KVV | Copper conductor PVC insulated PVC sheathed control cable |
KVVP2 | Copper conductor PVC insulated PVC sheathed copper tape screened control cable |
KVV22 | Copper conductor PVC insulated PVC sheathed steel tape armored control cable |
KVVP2-22 | Copper conductor PVC insulated PVC sheathed copper tape screened, steel tape armored control cable |
KVVR | Copper conductor PVC insulated PVC sheathed control flexible cable |
KVV32 | Copper conductor PVC insulated PVC sheathed steel wire armored control cable |
KVVP2-32 | Copper conductor PVC insulated PVC sheathed copper tape screened steel wire armored control cable |
KYJV | Copper conductor XLPE insulated PVC sheathed control cable |
KYJVP2 | Copper conductor XLPE insulated PVC sheathed copper tape screened control cable |
KYJV22 | Copper conductor XLPE insulated PVC sheathed steel tape armored control cable |
KYJVP2-22 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel tape armored control cable |
KYJV32 | Copper conductor XLPE insulated PVC sheathed steel wire armored control cable |
KYJVP2-32 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel wire armored control cable |
ConstructionÂ

Â
4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour
Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc.Â
Characteristics and Applications
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V.
The main features of the flame retardant PVC control cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands of flame retardant property.Â
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places necessary to resist fire.Â
Â
KVV, ZC-KVV
Number of cores  x Nominal cross-section mm2 |
Kind of  conductor |
Reference  outside diameter  of cable mm |
Reference weight of cable kg/km |
Max.D.C.  resistance  at 20ºC Ω/km |
Min.insulation   resistance    at 70ºC MΩ·km |
2 x 0.75 | 1 | 7.2 | 61 | 24.5 | 0.012 |
2 x 0.75 | 2 | 7.5 | 65 | 24.5 | 0.014 |
2 x 2.5 | 1 | 9.6 | 124 | 7.41 | 0.01 |
2 x 2.5 | 2 | 10.2 | 135 | 7.41 | 0.01 |
2 x 10 | 2 | 15.7 | 377 | 1.83 | 0.0065 |
5 x 0.75 | 1 | 8.7 | 101 | 24.5 | 0.012 |
5 x 0.75 | 2 | 9.1 | 108 | 24.5 | 0.014 |
5 x 2.5 | 1 | 12.7 | 247 | 7.41 | 0.01 |
5 x 2.5 | 2 | 13.4 | 267 | 7.41 | 0.01 |
5 x 10 | 2 | 20.4 | 769 | 1.83 | 0.0065 |
10 x 0.75 | 1 | 11.6 | 176 | 24.5 | 0.012 |
10 x 0.75 | 2 | 12.2 | 189 | 24.5 | 0.014 |
10 x 2.5 | 1 | 17.2 | 447 | 7.41 | 0.01 |
10 x 2.5 | 2 | 18.2 | 483 | 7.41 | 0.01 |
10 x 10 | 2 | 28.4 | 1452 | 1.83 | 0.0065 |
30 x 0.75 | 1 | 17.6 | 450 | 24.5 | 0.012 |
30 x 0.75 | 2 | 18.6 | 483 | 24.5 | 0.014 |
30 x 2.5 | 1 | 26 | 1167 | 7.41 | 0.01 |
30 x 2.5 | 2 | 27.6 | 1262 | 7.41 | 0.01 |
61 x 0.75 | 1 | 23.8 | 857 | 24.5 | 0.012 |
61 x 0.75 | 2 | 25.1 | 906 | 24.5 | 0.014 |
61 x 2.5 | 1 | 36 | 2320 | 7.41 | 0.01 |
61 x 2.5 | 2 | 38.3 | 2509 | 7.41 | 0.01 |
Our company

Workshop

Customers

Certificates

Â
1. Are you a trading company or manufacture?
We are a wire and cable Manufacturer with 30 years history almostly, our factory located in Qingyuan, Guangdong Province, China. Â
2. What is your main product?
As one of leading cable manufacturers in China, we are specialized in power cables with rated voltage up to 35kV, common type, fire-resistance and flame retardant PVC cable with voltage up to 1kV, control cable of 450/750V, PVC insulated cable and wire, AAC, ACSR, ACSR/AS, heat-resistant Aluminum Alloy Conductor and aerial insulated cable up to 35kV, which covers 8 series with more than 3000 items.
3. Can you offer me a free sample?
 Yes, sample is free but the freight charge should be borne by you.
Â
4.How is the payment?
T/T, L/C is acceptable.
Â
5. What is the lead time for mass production?
It depends on the order quantity and the season you place the order. Normally within 1 month.
6.Do you accept OEM or ODM?
Yes, we accept OEM and ODM. Your logo and company name can be printed on our products.
7.Do you have after-sale service?
Yes, 12 months warranty. Â
Contact us:
Sherry Zhang
Mobile     +86 18565101089
Watapp  +86 18565101089
Facebook +86 18565101089
Type and NameÂ
Type | Name |
KVV | Copper conductor PVC insulated PVC sheathed control cable |
KVVP2 | Copper conductor PVC insulated PVC sheathed copper tape screened control cable |
KVV22 | Copper conductor PVC insulated PVC sheathed steel tape armored control cable |
KVVP2-22 | Copper conductor PVC insulated PVC sheathed copper tape screened, steel tape armored control cable |
KVVR | Copper conductor PVC insulated PVC sheathed control flexible cable |
KVV32 | Copper conductor PVC insulated PVC sheathed steel wire armored control cable |
KVVP2-32 | Copper conductor PVC insulated PVC sheathed copper tape screened steel wire armored control cable |
KYJV | Copper conductor XLPE insulated PVC sheathed control cable |
KYJVP2 | Copper conductor XLPE insulated PVC sheathed copper tape screened control cable |
KYJV22 | Copper conductor XLPE insulated PVC sheathed steel tape armored control cable |
KYJVP2-22 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel tape armored control cable |
KYJV32 | Copper conductor XLPE insulated PVC sheathed steel wire armored control cable |
KYJVP2-32 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel wire armored control cable |
ConstructionÂ

Â
4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour
Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc.Â
Characteristics and Applications
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V.
The main features of the flame retardant PVC control cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands of flame retardant property.Â
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places necessary to resist fire.Â
Â
KVV, ZC-KVV
Number of cores  x Nominal cross-section mm2 |
Kind of  conductor |
Reference  outside diameter  of cable mm |
Reference weight of cable kg/km |
Max.D.C.  resistance  at 20ºC Ω/km |
Min.insulation   resistance    at 70ºC MΩ·km |
|||||||||||
2 x 0.75 | 1 | 7.2 | 61 | 24.5 | 0.012 | |||||||||||
2 x 0.75 | 2 | 7.5 | 65 | 24.5 | 0.014 | |||||||||||
2 x 2.5 | 1 | 9.6 | 124 | 7.41 | Lan Modules and Pluse Transformer Low-frequency power transformers use high-speed power transistors to invert the DC to AC, but drive transistors at the same frequency (60 Hz or 50Hz). They are widely used in small tpye electical appliances,such as air-conditioner VCD,UPS power supply,Acoustics etc.
Features:
FAQ 1-MOQ? We will work hard to fit your MOQ .Small purchase quantity is ok. 2-Payment term? T/T, Western Union, Paypal, Credit Card 3-Delivery port? Shenzhen, Guangzhou, Zhongshan, Hongkong. 4-Shipping date? About 7 days when we check the payment. 5-Do you produce the core and bobbin by yourself Yes.we have 2 head company,1 subsidiary company.one is bobbin factory,one is core factory,last one is transformer factory. 6-Where is your factory? In ShaanxI
Lan Transformer,Dual Lan Transformer,Ppt Lan Transformer,Port Card Lan Transformer Shaanxi Magason-tech Electronics Co.,Ltd , https://www.magason-tech.com |