Withstand voltage of LED lighting fixtures and countermeasures
Release date: 2018-06-08 Source: Lighting industry information
The leakage current here refers specifically to the leakage current generated in the withstand voltage test, which is the alarm threshold we set in the test. The human body's response to current is: perceptual current: male 1.1mA, female 0.7mA; get rid of current: male 9mA, female 6mA (probability 99.5%); lethal current (ventricular fibrillation current): 50mA (current duration exceeds heartbeat cycle) , 500mA (current duration is less than 0.1 seconds).
When the current flowing through the human body exceeds 10 mA, there is a danger of electric shock. Therefore, in general, the leakage current standard of the type test is defined as 5 mA. In GB 7000.1, the type test part does not clearly specify the leakage current in the withstand voltage test, and the value of this value is clearly specified in the factory type test of the appendix.
Withstand voltage test and breakdown test
The standard specifies the specific voltage value at the time of the test. After the withstand voltage test, it can only indicate that the insulation structure of the product can withstand the test voltage, and it cannot indicate how much the insulation structure of the product can withstand. If the application of insulation materials and the design of electrical equipment are required, when it is necessary to measure the dielectric strength, a breakdown test is required. The breakdown test is to test the voltage at which the dielectric is broken down. When the electric field strength exceeds a certain limit, the relationship between the current passing through the medium and the voltage applied to the medium does not conform to Ohm's law, but increases abruptly.
Some customers require a one-minute test according to the type test standard, which is “one harm to the productâ€: first, it may reduce the yield of the product; second, although it passes the test, it may damage part of the insulation structure, so that Product safety is reduced; third, some components may be damaged, so that the quality of the product is reduced and the life is shortened. Passing the withstand voltage test does not mean that the lamp is intact. In many cases, LED lamp beads can pass the pressure type test, but it will cause the lamp to be extinguished, but the actual life of the lamp will be greatly reduced due to the delay.
Test Methods
1. Check that the main power switch of the withstand voltage tester is in the "off" position.
2. Unless the instrument is specially designed, all uncharged metal parts must be reliably grounded.
3. Connect the wires or terminals of all power input terminals of the device under test.
4. Close all power switches, relays, etc. of the device under test.
5. Adjust the test voltage of the withstand voltage tester to zero.
6. Connect the high voltage output line (usually red) of the withstand voltage tester to the power input of the device under test.
7. Connect the loop ground wire (usually black) of the withstand voltage tester to the accessible, uncharged metal portion of the device under test.
8. Close the main power switch of the withstand voltage tester and slowly raise the secondary voltage of the instrument to the required value. Generally, the boosting speed does not exceed 500 V/sec.
9. Maintain this test voltage for a specified period of time.
10. Slowly lower the test voltage.
11. Disconnect the main power switch of the withstand voltage tester. First disconnect the high voltage output line of the withstand voltage tester, and then disconnect the grounding wire of the withstand voltage tester circuit.
Common ways to improve pressure resistance
Adding an isolation transformer, and effectively reducing the withstand voltage value of the secondary line through the transformer;
Increase the strength of the insulating medium, such as rubber, add insulating gaskets;
Select a circuit board with high dielectric layer pressure resistance;
Increase the creepage distance of the board.
As the circuit board where the lamp bead is arranged, the creepage distance and the wiring space are contradictory. In order to increase the creepage distance, the wiring space can only be compressed as much as possible. Try to avoid sharp objects to reduce the scratching of the insulation or the breakdown of the voltage due to the tip discharge. If you try to reduce the use of self-tapping screws; when designing the circuit board, apply copper at right angles and do over-treatment.
More lighting information in the lamp billion network https:// .
Label: lamps wholesale lighting procurement lamps to join billion lamp network
Draw-wire sensors of the wire sensor series measure with high linearity across the entire measuring range and are used for distance and position measurements of 100mm up to 20,000mm. Draw-wire sensors from LANDER are ideal for integration and subsequent assembly in serial OEM applications, e.g., in medical devices, lifts, conveyors and automotive engineering.
Linear Encoder,Digital Linear Encoder,Draw Wire Sensor,1500Mm Linear Encoder
Jilin Lander Intelligent Technology Co., Ltd , https://www.jilinlandermotor.com